Skip to main navigation Skip to search Skip to main content

The flexural strength of Y-TZP coated with carbonate apatite for dental implant material

  • A. Wenny Awalia
  • , Taufik Sumarsongko
  • , Rasmi Rikmasari
  • , Andrie Harmaji
  • , Arief Cahyanto
  • Padjadjaran University
  • Institut Teknologi dan Sains Bandung

Research output: Chapter in Book/Report/Conference proceedingChapterpeer-review

2 Scopus citations

Abstract

In order to gain acceleration of the osseointegration process after implant placement, micro retention using inorganic elements such as Hydroxyapatite (HA) were commonly used as a coating material in dental implant. Meanwhile, another inorganic material such as Carbonate Apatite (CO3Ap) has been known as bone substitute for decades. The purpose of this study is to investigate the flexural strength of Yttria-Stabilized Zirconia (Y-TZP) as dental implant material after being coated with CO3Ap. Ten specimens of Y-TZP were divided into two groups. The first group was coated with CO3Ap while other groups without coatings were used as the control. Biaxial flexural strength was determined using piston on three balls-technique and data were evaluated by statistical analysis. The specimens surface were analyzed through images taken by Scanning Electron Microscope (SEM). As the result, this study showed that there was no statistically significant found between the group with coating and the control group (p>0.05). The biaxial flexural strength’s mean of the group with coating and control were 212.80 MPa and 209.35 MPa; while micro Vickers hardness’ means were 229.56 HV and 245.40 HV. It can be concluded that there was no difference in the mean flexural strength between Y-TZP before and after coating.

Original languageEnglish
Title of host publicationKey Engineering Materials
PublisherTrans Tech Publications Ltd
Pages131-137
Number of pages7
DOIs
StatePublished - 2019
Externally publishedYes

Publication series

NameKey Engineering Materials
Volume829
ISSN (Print)1013-9826
ISSN (Electronic)1662-9795

Keywords

  • Carbonate apatite coating
  • Dental implant material
  • Flexural strength
  • Y-TZP

Fingerprint

Dive into the research topics of 'The flexural strength of Y-TZP coated with carbonate apatite for dental implant material'. Together they form a unique fingerprint.

Cite this