Refined speckle contrast estimation in OCT based on compensation of scattering-related distortions of speckle pattern parameters

  • Lev A. Matveev
  • , Alexander A. Sovetsky
  • , Alexander L. Matveyev
  • , I. Alex Vitkin
  • , Maher Assaad
  • , Vladimir Y. Zaitsev
  • Russian Academy of Sciences
  • Ajman University
  • University of Toronto
  • Princess Margaret Cancer Centre

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Speckle contrast (SC) parameters in optical coherence tomography (OCT) scans are formed by the interplay of several factors—local level of optical wave backscattering by the material inhomogeneities, parameters of spatial distribution of the latter and the degree of cumulative optical wave attenuation during its fourth-and-back propagation. For the optical wavelengths used in OCT, this attenuation is usually dominated by the influence of scattering in the visualized turbid tissues rather than by absorption. For sufficiently high concentrations of scatterers (at least a few scatterers in the coherence volume) characterized by comparable scattering strengths and a fairly homogeneous distribution in space, the interference of locally scattered waves should be characterized by a Rayleigh distribution of speckle amplitudes, for which the local SC tends to 0.52. Equivalently, in terms of speckle intensities, the local SC tends to unity. Local spatial inhomogeneities or strongly uneven scattering strengths lead to the appearance of increased values of SC, which may serve as a diagnostic feature of some tissue components in OCT images. At the same time, in comparison to surface speckles formed by coherent-light scattering from rough surfaces, OCT-beam attenuation during its fourth-and-back propagation may introduce intensity inhomogeneities in OCT scans even for homogeneous tissue areas. This effect results in artefactual distortion of the visible SC in comparison with the above-mentioned expected value. Moreover, the presence of individual strong scatterers may additionally non-locally distort SC values due to the appearance of elongated shadows below such scatterers, which causes lateral inhomogeneities in OCT scans. Here, we propose a refined SC parameter, which is cleaned from distorting scattering-related effects in both axial and lateral directions. Depth-resolved estimation of the optical attenuation coefficient is used to restore attenuation-free OCT scans, for which the refined SC is estimated. The efficiency of the proposed approach is demonstrated using both digital OCT phantoms with highly controlled properties and experimental OCT data.

Original languageEnglish
Article number015601
JournalLaser Physics Letters
Volume22
Issue number1
DOIs
StatePublished - 1 Jan 2025

Keywords

  • OCT speckles
  • optical attenuation coefficient
  • optical coherence tomography
  • speckle contrast