Skip to main navigation Skip to search Skip to main content

Numerical analysis of the magnetic field impact on hydrothermal characteristics of a microchannel heatsink with Fe3O4 ferrofluid and various pin-fin shapes

  • Tao Hai
  • , Kamal Sharma
  • , Riyam K. Marjan
  • , Babak Farhang
  • , Mohamed H. Mahmoud
  • , Hassan Fouad
  • , Walid El-Shafai
  • Qiannan Normal College for Nationalities
  • Ankang University
  • Guizhou University
  • GLA University
  • Al-Mustaqbal University College
  • Aalborg University
  • King Saud University
  • Helwan University
  • Menoufia University

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Enhancing the hydrothermal proficiency of thermal management devices by integrating active and passive heat transfer techniques is possible. Under magnetic field (MF), pin–fin heat sinks have rarely been studied in terms of frictional losses and coefficient of heat transfer (h). Here, with a nanoparticle concentration ratio of 2%, Fe3O4 ferrofluid flow inside a pin–fin heatsink was analyzed numerically considering various pin–fin shapes (rhumbas, squares, circles, and triangles) for absenteeism (WO) and attendance (W) of MF. In the results, the greatest and lowest gains for h were 13.12% and 8.8%, respectively, utilizing MF and Re = 200, for the circular and triangular heatsinks, which would be reduced to 5.36% and 2.41% by increasing Re to 500. In addition, h (and thermal resistance factor) in triangular configuration is 7.82–10.86% (and 4.98–8.68%) and 3.23–8.08% (1.94–6.22%) greater (and smaller) than that in the circular design under two scenarios of MF. Moreover, MF brings about a reduction of 1.86–0.60%, 1.61–0.46%, 1.71–0.54%, and 1.16–0.24% in Tm,CPU for the circular, square, rhumbas, and triangular configurations, respectively, within the Re range of 200–500. Although, when MF is present, pressure loss escalates by almost 6.39%, 4.97%, 3.60%, and 2.92% at Re numbers of 200, 300, 400, and 500 for each configuration, with the maximum pressure loss for triangular heatsink compared to the other arrangements. PEC factors at different Re numbers range from 1.51 to 1.87, suggesting an improved heatsink hydrothermal performance under MF impact compared to absenteeism of that. The highest/lowest PEC values at Re numbers 200 and 500 are associated with the rhumbas/triangular (1.871/1.782) and Triangular/square (1.547/1.496) configurations, respectively.

Original languageEnglish
Article number171102
JournalJournal of Magnetism and Magnetic Materials
Volume585
DOIs
StatePublished - 1 Nov 2023
Externally publishedYes

Keywords

  • FeO ferrofluid
  • Hydrothermal behavior
  • Magnetic field
  • Numerical investigation
  • Pin-fin heatsink

Fingerprint

Dive into the research topics of 'Numerical analysis of the magnetic field impact on hydrothermal characteristics of a microchannel heatsink with Fe3O4 ferrofluid and various pin-fin shapes'. Together they form a unique fingerprint.

Cite this