Skip to main navigation Skip to search Skip to main content

Integrating Millimeter-Wave FMCW Radar for Investigating Multi-Height Vital Sign Monitoring

  • Fahad Ayaz
  • , Basim Alhumaily
  • , Sajjad Hussain
  • , Lina Mohjazi
  • , Muhammad Ali Imran
  • , Ahmed Zoha
  • University of Glasgow

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

3 Scopus citations

Abstract

The millimetre-wave (mmWave) based frequency-modulated continuous wave (FMCW) radar is a pioneering technique for non-invasive vital sign monitoring, specifically designed for integration within 5G/Beyond 5G (B5G) network environments. In this study, we focus on evaluating the accuracy of the FMCW radar in measuring heart rate (HR) and respiratory rate (RR) at various heights relative to the subject's chest. To harness the low-latency benefits of advanced wireless technologies, the mmWave radar operates in tandem with the real-time data-capture adapter (DCA1000) evaluation module, facilitating the high-speed transmission of vital sign data. We employed two signal-processing methodologies, fast fourier transform (FFT) and peak count, to analyze and validate the radar's precision and consistency against reference sensors. Our results underscore the effectiveness of the peak count method, which demonstrates superior accuracy, with mean absolute error (MAE) values of 5.33 breaths/min for RR and 4.03 beats/min for HR, along with root mean square error (RMSE) values of 5.30 breaths/min for RR and 4.30 beats/min for HR, consistent across all tested heights. The proposed system significantly enhances the reliability and responsiveness of next-generation healthcare systems, offering a robust solution for patient monitoring in various interactive and intelligent real-time settings.

Original languageEnglish
Title of host publication2024 IEEE Wireless Communications and Networking Conference, WCNC 2024 - Proceedings
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9798350303582
DOIs
StatePublished - 2024
Externally publishedYes
Event25th IEEE Wireless Communications and Networking Conference, WCNC 2024 - Dubai, United Arab Emirates
Duration: 21 Apr 202424 Apr 2024

Publication series

NameIEEE Wireless Communications and Networking Conference, WCNC
ISSN (Electronic)1558-2612

Conference

Conference25th IEEE Wireless Communications and Networking Conference, WCNC 2024
Country/TerritoryUnited Arab Emirates
CityDubai
Period21/04/2424/04/24

Keywords

  • DCA1000
  • FFT
  • Non-Invasive
  • Peak Count
  • Sensing
  • Vital Sign
  • mmWave Radar

Fingerprint

Dive into the research topics of 'Integrating Millimeter-Wave FMCW Radar for Investigating Multi-Height Vital Sign Monitoring'. Together they form a unique fingerprint.

Cite this