Skip to main navigation Skip to search Skip to main content

In vitro Dissolution Profile at Different Biological pH Conditions of Hydroxychloroquine Sulfate Tablets Is Available for the Treatment of COVID-19

  • Thirupathi Dongala
  • , Naresh Kumar Katari
  • , Santhosh Kumar Ettaboina
  • , Anand Krishnan
  • , Murtaza M. Tambuwala
  • , Kamal Dua
  • Aurex Laboratories LLC
  • Gandhi Institute of Technology and Management
  • University of The Free State
  • Ulster University
  • University of Technology Sydney
  • University of Newcastle
  • Shoolini University of Biotechnology and Management Sciences

Research output: Contribution to journal › Article › peer-review

12 Scopus citations

Abstract

Hydroxychloroquine sulfate is one of an extensive series of 4-aminoquinolines with antimalarial activity. Moreover, it is used for the treatment of rheumatoid arthritis. Sometimes, hydroxychloroquine sulfate is beneficial for the treatment of autoimmune diseases. Based on recent clinical experiments, it is exploited for the treatment of COVID-19, coronavirus across the globe. The chromatogram separation was achieved by using Agilent, Zorbax C8, 250 mm × 4.6 mm i.d., column. The buffer consists of 0.01 M of 1-pentane sulfonic acid and 0.02% of orthophosphoric acid in purified water. Mixed buffer, acetonitrile, and methanol (800:100:100 v/v). The flow rate was 1.0 ml min−1, and injection volume was 10 μl. Detection was made at 254 nm by using a dual absorbance detector (DAD). The reversed-phase high-performance liquid chromatography (RP-HPLC) method has been developed and validated as per the current International Conference on Harmonization (ICH) guidelines to estimate hydroxychloroquine sulfate tablets. As part of method validation, specificity, linearity, precision, and recovery parameters were verified. The concentration and area relationships were linear (R2 > 0.999) over the concentration range of 25–300 μg ml−1 for hydroxychloroquine (HCQ). The relative standard deviations for precision and intermediate precision were <1.5%. The proposed RP-HPLC generic method was applied successfully to evaluate the in vitro dissolution profile with different pH conditions such as 0.1 N HCl, pH 4.5 acetate buffer, and pH 6.8 phosphate buffers as US-marketed reference products.

Original languageEnglish
Article number613393
JournalFrontiers in Molecular Biosciences
Volume7
DOIs
StatePublished - 14 Jan 2021
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • coronavirus disease 2019
  • dissolution
  • hydroxychloroquine sulfate
  • pH
  • validation

Fingerprint

Dive into the research topics of 'In vitro Dissolution Profile at Different Biological pH Conditions of Hydroxychloroquine Sulfate Tablets Is Available for the Treatment of COVID-19'. Together they form a unique fingerprint.

Cite this