Skip to main navigation Skip to search Skip to main content

Cost-effective preparation of cobalt oxide/nickel oxide composite for the efficient non-enzymatic electrochemical detection of uric acid

  • Arslan Uddin Qureshi
  • , Humaira Khan
  • , Aneela Tahira
  • , Shaista Bano Memon
  • , Asma Hayat
  • , Saba Naz
  • , Muhammad Ali Bhatti
  • , Aftab Ahmed Khand
  • , Matteo Tonezzer
  • , Brigitte Vigolo
  • , Elmuez Dawi
  • , Rafat M. Ibrahim
  • , Zafar Hussain Ibupoto
  • University of Sindh
  • Shah Abdul Latif University
  • Turbat University
  • University of Cagliari
  • Institut Jean Lamour
  • Taibah University

Research output: Contribution to journalArticlepeer-review

Abstract

This study underscores the potential of Cucumis melo juice as a sustainable reducing, structure-directing, capping, and stabilizing agent used to modify the surface characteristics, shape, and size of nickel oxide (NiO) through a modified hydrothermal process. This modification results in a significant alteration of the optical band gap of NiO, which is subsequently utilized in combination with cobalt oxide (Co3O4) to synthesize Co3O4/NiO composites. The physical and optical properties of the synthesized materials, including their morphology, crystal structure, and optical behavior, were thoroughly examined using advanced analytical techniques, such as scanning electron microscopy (SEM), powder X-ray diffraction (XRD), and UV-visible spectrometry, while the chemical bonds within these materials were investigated through Fourier transform infrared (FTIR) spectroscopy. Among the composites, the reduced Co3O4/NiO-1 composite, characterized by an optical bandgap of 2.07 eV, exhibited the most pronounced activity for electrochemical non-enzymatic detection of uric acid (UA). This particular composite demonstrated a broad operational range, capable of detecting UA at concentrations from 0.1 mM to 16 mM using the chronoamperometric method. Additionally, it achieved a high sensitivity of 7.63 × 10−4 µA mM−1 cm−2 and a low detection limit of 0.005 mM when tested in a 0.1 M phosphate buffer solution at a pH of 7.3.

Original languageEnglish
Pages (from-to)25758-25771
Number of pages14
JournalRSC Advances
Volume16
Issue number28
DOIs
StatePublished - 13 May 2026

Fingerprint

Dive into the research topics of 'Cost-effective preparation of cobalt oxide/nickel oxide composite for the efficient non-enzymatic electrochemical detection of uric acid'. Together they form a unique fingerprint.

Cite this