Skip to main navigation Skip to search Skip to main content

A critical mini-review on challenge of gaseous O3 toward removal of viral bioaerosols from indoor air based on collision theory

  • University of Maragheh
  • Yuzuncu Yil University
  • University of Amsterdam
  • Shaanxi University of Science and Technology

Research output: Contribution to journalReview articlepeer-review

13 Scopus citations

Abstract

COVID-19, a pandemic of acute respiratory syndrome diseases, led to significant social, economic, psychological, and public health impacts. It was not only uncontrolled but caused serious problems at the outbreak time. Physical contact and airborne transmission are the main routes of transmission for bioaerosols such as SARS-CoV-2. According to the Centers for Disease Control (CDC) and World Health Organization (WHO), surfaces should be disinfected with chlorine dioxide, sodium hypochlorite, and quaternary compounds, while wearing masks, maintaining social distance, and ventilating are strongly recommended to protect against viral aerosols. Ozone generators have gained much attention for purifying public places and workplaces’ atmosphere, from airborne bioaerosols, with specific reference to the COVID-19 pandemic outbreak. Despite the scientific concern, some bioaerosols, such as SARS-CoV-2, are not inactivated by ozone under its standard tolerable concentrations for human. Previous reports did not consider the ratio of surface area to volume, relative humidity, temperature, product of time in concentration, and half-life time simultaneously. Furthermore, the use of high doses of exposure can seriously threaten human health and safety since ozone is shown to have a high half-life at ambient conditions (several hours at 55% of relative humidity). Herein, making use of the reports on ozone physicochemical behavior in multiphase environments alongside the collision theory principles, we demonstrate that ozone is ineffective against a typical bioaerosol, SARS-CoV-2, at nonharmful concentrations for human beings in air. Ozone half-life and its durability in indoor air, as major concerns, are also highlighted in particular. Graphical Abstract: [Figure not available: see fulltext.].

Original languageEnglish
Pages (from-to)84918-84932
Number of pages15
JournalEnvironmental Science and Pollution Research
Volume30
Issue number36
DOIs
StatePublished - Aug 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bioaerosol
  • Collision theory
  • Disinfection
  • Half-life
  • Indoor air
  • Ozone

Fingerprint

Dive into the research topics of 'A critical mini-review on challenge of gaseous O3 toward removal of viral bioaerosols from indoor air based on collision theory'. Together they form a unique fingerprint.

Cite this